Sign In | Join Free | My entremaqueros.com |
|
Brand Name : United electrical
Model Number : HZ-DL
Certification : ISO9001
Place of Origin : Wuhan
MOQ : 100pcs
Price : Price negotiable
Delivery Time : 20 work days
Packaging Details : Carton with wrapping film and pallet
Payment Terms : TT / LC at sight
Supply Ability : 10000 pcs / month
Material : silicone rubber
Type : Insulated termination/jont
Application : 11KV/24kV/35kV
Tensile Strength : 10.4Mpa
Rated Voltage : 11KV/24kV/35kV
Cable accessories type : Cold shrink
Cold Shrink Silicone Rubber Electric Cable Accessories Indoor Termination
Product features:
1. Cold shrinkable cable accessories adopt world renowned brand liquid/solid silicone rubber material. The products are with excellent insulation, anti-tracking, rebound resistance, heat/cold resistance, ozone resistance, anti-aging, and good dielectric properties, and can be used under various harsh conditions.
2. Geometric stress control method.
3. Standards compliance: IEC60502
4. Cold installation, easy and safe without using fire, just by pulling the spiral.
Product Dimensions
The size of 12/24kV Cold Shrinkable Indoor Termination for Cable to 35-630mm², Unit in mm
The size of 12/24kV Cold Shrinkable Outdoor Termination for Cable to 35-630mm², Unit in mm
The size of 12/24kV Cold Shrinkable Straight Joint for Cable to 35-630mm², Unit in mm
Rated Voltage | 8.7/15(17.5)kV | 12/20(24)kV | 18/30(36)kV | 26/35(40.5)kV |
Running voltage | 17.5kV | 24kV | 36kV | 40.5kV |
AC Withstand Voltage and DC Withstand Voltage | 39kV, 5min or 35kV, 15min, no flashover, no breakdown | 54kV,5min, or 48kV, 15min, no flashover, no breakdown | 81kV, 5min, or 72kV, 15min, no flashover, no breakdown | 117kV, 5min or 104kV, 15 min no flashover, no breakdown |
Partial Discharge | 15kV, PD≤5pC | 20kV, PD≤5pC | 30kV, PD≤5pC | 45kV, PD≤5pC |
Impulse Voltage Test | 95kV, ±10 times | 125kV, ±10 times | 170kV, ±10 times | 200kV, ±10 times |
Short Circuit Thermal Stability (Conductor) | 24kA, 2s twice, no visible damage | 25kA, 2s twice, no visible damage | 23kA, 2s twice, no visible damage | 25kA, 2s twice, no visible damage |
Short Circuit Dynamic Stability | 83kA, not less than 10ms, no visible damage | 63kA, not less than 10ms, no visible damage | 83kA, not less than 10ms, no visible damage | 88kA, not less than 10ms, no visible damage |
Constant Voltage Load Cycle | apply voltage 2.5U0 to conductor and heat to(90-95)ºC heat for 5h and cool for 3h, total 3 times | |||
Salt Spray Test | 1.25U0 1000h, no flashover, no breakdown, trip not more than 3 times, no obvious damage | |||
Humidity Test | 1.25U0 300h, no flashover, no breakdown, trip not more than 3 times, no obvious damage | |||
Long-time Running Temperature | -40ºC to 95ºC | |||
Short Circuit Temperature | 250ºC, lasting time less than 5s | |||
Cable Accessories Conductor Material |
copper, aluminum, copper&aluminum |
![]() |